The hypothetical purchase note “the charger must be quiet” leaves two laboratories free to answer different questions. One might evaluate a settled working load; another might listen during a port change. A listener’s report can identify an annoying sound without establishing a calibrated sound level, an electrical fault or a safety verdict.
Start with the customer task: where the product is expected to operate and which sound matters. The framework below turns that concern into a fillable requirement and an evidence decision. It supplies no charger measurements, universal acoustic limit or certification method. Qualified personnel in a controlled laboratory must own any testing.
Write a clause that can remain unresolved
Fill every bracket before requesting an acceptance decision. This is proposed purchasing language, not a quotation from a standard:
For [requirement ID, revision and owner], evaluate [model, sample and configuration] in [approved operating, port and load case], following [agreed conditioning rule]. Use [placement and microphone-geometry drawing] and report [metric, frequency weighting and applicable detector] over [defined observation interval]. Compare against [customer-approved criterion and uncertainty/decision rule] only when [background and measurement-chain validity requirements] are satisfied. Retain [raw-record references and separate listener or tonal observations]. Resolve missing fields with [named owner]; do not substitute defaults.
Use the following annotations to turn the sentence into a usable record rather than another vague promise.
| Clause field | Fill with | Leave unresolved when |
|---|---|---|
| Identified case | Sample, hardware revision, input condition, port allocation and actual load record | Only a marketing model family is named |
| Conditioning and interval | Agreed start event, settling rule, duration and treatment of interruptions | “After a while” is the only timing instruction |
| Placement | Support, orientation, surroundings and microphone location drawing | The second laboratory cannot reconstruct the geometry |
| Acoustic quantity | Full metric name, frequency weighting and applicable detector | The report says only “noise in dB” |
| Validity | Instrument-chain records and laboratory-approved background rule | The charger contribution is obscured or validity is undocumented |
| Decision | Criterion authority, uncertainty rule, reviewer and disposition | No approved basis exists for pass or fail |
No bracket implies a standard distance, duration, load or dBA ceiling. Agree those choices before comparing results, not after seeing which conditions produce the lowest number.
Bind sound to the actual operating case
Texas Instruments’ UCC28780 controller datasheet describes operating modes across load and line conditions and discusses audible-noise concerns in its burst-control explanation. That is a concrete example of state-dependent component operation. It does not identify the controller inside an offered ChargeKeku charger, demonstrate that charger’s acoustic performance or diagnose the cause of a sound.
Give required no-load, defined light-load, working-load and simultaneous-port conditions separate case IDs. Include only cases relevant to the agreed customer task. Keep startup or change events separate from settled intervals; an event record should identify what changed and when. Record actual operating conditions rather than assuming a device name uniquely defines its load.
Use PPS operating-state acceptance for the electrical operating-point question. It can supply a referenced state record, but a voltage-accuracy result is not an acoustic result.
Make the scene and measurement chain reproducible
Brüel & Kjær’s September 1984 Measuring Sound booklet discusses calibration, background influence and report fields including geometry, weighting, environment and operating load. These are historical measurement principles, not proof of compliance with a current acoustic standard. This article does not adopt the booklet’s numerical background-correction rule or occupational limits as charger acceptance criteria.
Attach a scene drawing that identifies the closed charger, support surface, orientation, microphone and relevant surroundings. Retain the background record and its relationship to that geometry and interval. Ask the laboratory to explain whether background and instrument limitations permit the intended conclusion; an obscured contribution is not evidence of silence. A sound-pressure result at one position is not a sound-power declaration.

Retain instrument, microphone and calibrator identities, calibration references and session-verification records. Keep listener comments in a separate field with the operating case and observation time. An unvalidated phone clip is qualitative evidence. A phone-based instrument with a documented, suitable calibration and measurement chain is not excluded merely because it uses a phone; judge the complete chain and method, not the device category.
Name the quantity, not just the weighting
NTi Audio’s May 2026 XL2 operating manual distinguishes integrated LAeq from LAFmax over the measurement period and separately describes running or sliding Leq windows. It is a useful instrument-method example, not a requirement to buy that analyzer or adopt its selectable ranges.
LAeq,T is the integrated, energy-equivalent A-weighted sound level over interval T. LAFmax is the maximum of the Fast-time-weighted A-weighted level during the observation interval, not an instantaneous peak. “Fast” therefore does not belong indiscriminately on every metric. Identify frequency weighting, integration interval and detector/time weighting where applicable; one generic settings label is insufficient.
State the start and end rules even when both laboratories report the same metric. A running-window value, a whole-run average and an event maximum answer different questions. Preserve interruptions and excluded intervals rather than silently changing the comparison window.
Work five validity cases before deciding
These five cases are hypothetical dossier problems, not charger test results. “Hold” means the named acceptance question remains unresolved, not that the product has automatically failed.
| Dossier case | What the record cannot establish | Appropriate disposition |
|---|---|---|
| Background differs or obscures the contribution | A directly comparable charger level | Hold the numeric comparison; obtain a documented validity decision |
| Load, port state or placement changed | That a difference belongs to the same operating case | Separate the cases and request matched records |
| Observation windows differ | That averages or maxima cover the same event or interval | Reconcile the timing records before comparison |
| A tonal complaint has only an overall average | Whether the reported character concern was addressed | Agree suitable character or spectral evidence; invent no tonality penalty |
| Conditions, validity and approved criterion match | Anything beyond the named acoustic requirement | Apply the agreed uncertainty/decision rule and record the supported scope |
Hand over evidence, not a repair theory
Retain the requirement revision, raw-record locations, validity decision and reviewer’s disposition together. A missing record is not a failure measurement; an adverse valid result should not be relabeled as missing paperwork. Route questions about sustained power or temperature to thermal derating and sustained-power testing, not to a theory derived from sound alone.
For a ChargeKeku sourcing enquiry, request a model-specific acoustic requirement review with the completed clause and unresolved fields. This requests documentation, not a silence guarantee or an assurance that a report already exists.
Keep the enclosure closed. This worksheet does not authorize mains work, earth disconnection, component tuning or fault injection. The qualified laboratory determines any necessary work under its controlled procedures; the buyer defines the evidence question, not a repair experiment.