Audible Charger Noise: Write a Repeatable Acceptance Requirement

The hypothetical purchase note “the charger must be quiet” leaves two laboratories free to answer different questions. One might evaluate a settled working load; another might listen during a port change. A listener’s report can identify an annoying sound without establishing a calibrated sound level, an electrical fault or a safety verdict.

Start with the customer task: where the product is expected to operate and which sound matters. The framework below turns that concern into a fillable requirement and an evidence decision. It supplies no charger measurements, universal acoustic limit or certification method. Qualified personnel in a controlled laboratory must own any testing.

Write a clause that can remain unresolved

Fill every bracket before requesting an acceptance decision. This is proposed purchasing language, not a quotation from a standard:

For [requirement ID, revision and owner], evaluate [model, sample and configuration] in [approved operating, port and load case], following [agreed conditioning rule]. Use [placement and microphone-geometry drawing] and report [metric, frequency weighting and applicable detector] over [defined observation interval]. Compare against [customer-approved criterion and uncertainty/decision rule] only when [background and measurement-chain validity requirements] are satisfied. Retain [raw-record references and separate listener or tonal observations]. Resolve missing fields with [named owner]; do not substitute defaults.

Use the following annotations to turn the sentence into a usable record rather than another vague promise.

Clause fieldFill withLeave unresolved when
Identified caseSample, hardware revision, input condition, port allocation and actual load recordOnly a marketing model family is named
Conditioning and intervalAgreed start event, settling rule, duration and treatment of interruptions“After a while” is the only timing instruction
PlacementSupport, orientation, surroundings and microphone location drawingThe second laboratory cannot reconstruct the geometry
Acoustic quantityFull metric name, frequency weighting and applicable detectorThe report says only “noise in dB”
ValidityInstrument-chain records and laboratory-approved background ruleThe charger contribution is obscured or validity is undocumented
DecisionCriterion authority, uncertainty rule, reviewer and dispositionNo approved basis exists for pass or fail

No bracket implies a standard distance, duration, load or dBA ceiling. Agree those choices before comparing results, not after seeing which conditions produce the lowest number.

Bind sound to the actual operating case

Texas Instruments’ UCC28780 controller datasheet describes operating modes across load and line conditions and discusses audible-noise concerns in its burst-control explanation. That is a concrete example of state-dependent component operation. It does not identify the controller inside an offered ChargeKeku charger, demonstrate that charger’s acoustic performance or diagnose the cause of a sound.

Give required no-load, defined light-load, working-load and simultaneous-port conditions separate case IDs. Include only cases relevant to the agreed customer task. Keep startup or change events separate from settled intervals; an event record should identify what changed and when. Record actual operating conditions rather than assuming a device name uniquely defines its load.

Use PPS operating-state acceptance for the electrical operating-point question. It can supply a referenced state record, but a voltage-accuracy result is not an acoustic result.

Make the scene and measurement chain reproducible

Brüel & Kjær’s September 1984 Measuring Sound booklet discusses calibration, background influence and report fields including geometry, weighting, environment and operating load. These are historical measurement principles, not proof of compliance with a current acoustic standard. This article does not adopt the booklet’s numerical background-correction rule or occupational limits as charger acceptance criteria.

Attach a scene drawing that identifies the closed charger, support surface, orientation, microphone and relevant surroundings. Retain the background record and its relationship to that geometry and interval. Ask the laboratory to explain whether background and instrument limitations permit the intended conclusion; an obscured contribution is not evidence of silence. A sound-pressure result at one position is not a sound-power declaration.

Conceptual scene separates a closed charger and microphone geometry from background, calibration-chain and listener-note records; no distance is prescribed.
Conceptual record layout, not an equipment setup or wiring plan. Geometry must be documented; no scale, distance, acoustic level or approved laboratory arrangement is implied.

Retain instrument, microphone and calibrator identities, calibration references and session-verification records. Keep listener comments in a separate field with the operating case and observation time. An unvalidated phone clip is qualitative evidence. A phone-based instrument with a documented, suitable calibration and measurement chain is not excluded merely because it uses a phone; judge the complete chain and method, not the device category.

Name the quantity, not just the weighting

NTi Audio’s May 2026 XL2 operating manual distinguishes integrated LAeq from LAFmax over the measurement period and separately describes running or sliding Leq windows. It is a useful instrument-method example, not a requirement to buy that analyzer or adopt its selectable ranges.

LAeq,T is the integrated, energy-equivalent A-weighted sound level over interval T. LAFmax is the maximum of the Fast-time-weighted A-weighted level during the observation interval, not an instantaneous peak. “Fast” therefore does not belong indiscriminately on every metric. Identify frequency weighting, integration interval and detector/time weighting where applicable; one generic settings label is insufficient.

State the start and end rules even when both laboratories report the same metric. A running-window value, a whole-run average and an event maximum answer different questions. Preserve interruptions and excluded intervals rather than silently changing the comparison window.

Work five validity cases before deciding

These five cases are hypothetical dossier problems, not charger test results. “Hold” means the named acceptance question remains unresolved, not that the product has automatically failed.

Dossier caseWhat the record cannot establishAppropriate disposition
Background differs or obscures the contributionA directly comparable charger levelHold the numeric comparison; obtain a documented validity decision
Load, port state or placement changedThat a difference belongs to the same operating caseSeparate the cases and request matched records
Observation windows differThat averages or maxima cover the same event or intervalReconcile the timing records before comparison
A tonal complaint has only an overall averageWhether the reported character concern was addressedAgree suitable character or spectral evidence; invent no tonality penalty
Conditions, validity and approved criterion matchAnything beyond the named acoustic requirementApply the agreed uncertainty/decision rule and record the supported scope

Hand over evidence, not a repair theory

Retain the requirement revision, raw-record locations, validity decision and reviewer’s disposition together. A missing record is not a failure measurement; an adverse valid result should not be relabeled as missing paperwork. Route questions about sustained power or temperature to thermal derating and sustained-power testing, not to a theory derived from sound alone.

For a ChargeKeku sourcing enquiry, request a model-specific acoustic requirement review with the completed clause and unresolved fields. This requests documentation, not a silence guarantee or an assurance that a report already exists.

Keep the enclosure closed. This worksheet does not authorize mains work, earth disconnection, component tuning or fault injection. The qualified laboratory determines any necessary work under its controlled procedures; the buyer defines the evidence question, not a repair experiment.

Sources

  • Brüel & Kjær — Measuring Sound, BR0047, September 1984: selected historical calibration, background, reporting and quantity principles; no current compliance claim.
  • NTi Audio — XL2 Operating Manual, May 2026, manual 4.93.02: selected sound-level metrics and observation-window context.
  • Texas Instruments — UCC28780 datasheet, revised February 2018: component operating-mode example, not finished-charger evidence.