A charger arrives with a large wattage on its box, several voltage/current lines on its label, and a manual showing a different two-port allocation. Which number belongs in the purchase specification? Do not resolve that question by selecting the largest figure. First establish whether the documents describe the same physical ports under the same conditions.
This is a procurement method for reconciling electrical-rating statements, not a legal labeling audit or a performance test. Its output is a controlled ledger: each claim has a configuration, an evidence reference and an owner for unresolved differences.
Freeze the identity before comparing numbers
Photograph the intact sample label and physical port names. Record the complete model, plug variant, declared input range, sample reference and any supplied hardware or firmware identifier. Do not open the charger to fill missing fields. Ask the supplier to identify the configuration instead.
Keep the manual revision, artwork revision, supplier rating declaration and offered-profile record together. A current web page and an older carton may refer to different builds. Preserve both versions and ask which governs the received sample; silently replacing the inconvenient document destroys the discrepancy trail.
If product selection is still open, use the broader wall-charger selection and PD-profile guide. This ledger starts later, when a particular sample and its claimed output need reconciliation.
Keep alternative states separate
Transcribe fixed voltage/current pairs as alternatives available in a stated port condition. A fixed Power Data Object, or PDO, is not another output to add to every other PDO on that port. For the ledger, calculate power only for one declared operating point at a time, then compare it with the corresponding declaration.
Keep a Programmable Power Supply, or PPS, envelope separate from those fixed pairs. Record its voltage range, current information, stated power ceiling and applicable restrictions as supplied. Do not multiply unrelated maximum endpoints and assume every point inside that imagined rectangle is available. If the envelope is unclear, leave the claim unresolved rather than manufacturing a rating.
Solo capability and simultaneous allocation also need different rows. A device drawing less than a printed maximum does not, by itself, establish a lower source ceiling. Ask for an offered-profile record tied to the exact configuration and port combination; distinguish what was offered, what was negotiated and what the device actually drew.
Two sources clarify the boundary, not your sample
Apple’s 35W Dual USB-C Port Power Adapter instructions describe allocation according to connected-device requirements. For that named product, a Mac laptop with an iPhone or iPad can receive up to 17.5W per device. A Mac laptop or iPhone paired with an Apple Watch or AirPods can receive up to 27.5W and 7.5W respectively. These are Apple’s product-specific examples, not a universal split or ChargeKeku results.
The USB-IF Source Power Requirements Test Specification, revision 0.79, dated May 24, 2021, defines cumulative maximum power using concurrently sourced port maxima. Its multi-port context also recognizes changing available resources as other ports take power. This is historical context for separating simultaneous states, not a statement of current certification requirements or mandatory label wording.
Build a ledger that can close a disagreement
Use one row per required combination and condition. Attach the following fields to every row rather than keeping evidence in an unindexed email thread:
- Sample reference, exact model, physical ports and document revisions.
- Input condition and any other stated restriction affecting that row.
- Fixed profiles or PPS envelope, with the original units preserved.
- Declared per-port ceilings and the explicit simultaneous total, if applicable.
- Offered-profile record, configuration identifier and evidence location.
- Discrepancy, responsible owner and the document needed for closure.
The following numbers are fictional teaching arithmetic. They are not Apple specifications, ChargeKeku specifications or laboratory measurements. The empty references must be completed from a real procurement file before this becomes an acceptance record.
| Fictional operating row | Arithmetic and comparison | Evidence still needed |
|---|---|---|
| C1 alone | 20V × 3.25A = 65W; compare only with C1-solo rating | Label/manual revision and C1 profile record |
| C2 alone | 20V × 3.25A = 65W; another solo option, not another simultaneous 65W | C2 declaration and configuration-bound record |
| C1 + C2 | 45W + 20W = 65W for this fictional allocation | Explicit combined-output table and matching record |
The first two rows cannot establish a 130W simultaneous claim. Equally, the third row does not disprove a 65W solo rating: it describes another condition. If a supplier states different allocations for different input conditions, retain separate rows and request their exact scope rather than averaging the numbers.

Assign a narrow hold and a closure condition
A discrepancy should stop the affected claim from advancing, not invite a purchasing team to diagnose internal circuitry. The table below proposes documentary dispositions. Agree the responsible reviewer and due date in the purchasing record.
| Finding | Immediate disposition | Closure evidence |
|---|---|---|
| Solo maxima were added into a combined claim | Hold that combined-output claim | Approved table naming the simultaneous ports and conditions |
| Label and manual show different conditions or revisions | Preserve separate rows; request an explanation | Exact-model clarification and corrected controlled documents where needed |
| Offered profiles differ from the declaration | Hold the affected rating conclusion | Configuration-bound evidence and a reconciled declaration |
| Only a controller data sheet supports the rating | Request finished-model evidence | Product-specific declaration and applicable records |
Texas Instruments’ TPS25750 overview describes a GUI that creates a configuration image for an application. It illustrates why a component description and an application configuration are different evidence objects. The page also marks TPS25750 as not recommended for new designs. This is not a component recommendation, a claim about ChargeKeku’s bill of materials, or proof of any finished charger’s profiles.
Close the record without broadening the approval
When every required row is reconciled, close only the rating-consistency review. Functional performance, safety applicability and market-specific marking obligations remain separate. Record the accepted revisions and any restricted claims so later artwork does not quietly restore an unsupported total.
If the question is instead a pause when another device connects, hand it to the dynamic port-sharing and brief-disconnect guide. This ledger does not replace connection-order or recovery evaluation.
For a sourcing enquiry, request model-specific rating evidence with the sample reference, required combinations and unresolved ledger rows. Ask for traceable documents, not a promise that a headline wattage covers every port at once.
Sources
- Apple — How to use the 35W Dual USB-C Port Power Adapter — published January 24, 2026; exact-product allocation examples.
- USB-IF — Source Power Requirements Test Specification, revision 0.79 — May 24, 2021; historical concurrent-power context only.
- Texas Instruments — TPS25750 product overview — application-configuration example and lifecycle notice; not finished-product evidence.