“Overvoltage protection” is incomplete purchasing language until it identifies the protected node, the condition being detected and the intended response. A component feature list can explain a mechanism without demonstrating what happens at an offered charger’s output. Start by disassembling the claim on paper, not by opening the charger.
This article provides an original framework for reviewing existing engineering and laboratory records. It contains no actual charger event, waveform, trip value or certification finding. Any electrical investigation belongs to qualified personnel in a controlled laboratory; the worksheet does not authorize a setup or fault experiment. The decision here is how narrowly the evidence supports a claim, not whether every connected device is guaranteed protection.
Three component examples expose different scope traps
Texas Instruments’ UCC28740 controller datasheet describes sampling reflected output voltage at its VS input for output-overvoltage protection. Its fault-protection section describes stopping switching, discharging the controller supply to its undervoltage-lockout threshold, then returning to startup. This is a controller-specific sensing and reset sequence. An internal sense threshold is not directly a USB receptacle limit, and a controller restart is not evidence that useful charging resumed.
The TPS25947 datasheet distinguishes suffix-specific protection functions. Its TPS259470x/4x variants provide overvoltage lockout: an input-related condition causes output power to turn off, with return governed by the falling threshold. TPS259472x variants instead clamp their output during input overvoltage. The document also describes suffix-dependent behavior after thermal shutdown during extended clamping. Do not merge lockout, clamping and recovery into one generic “OVP works” statement; the exact variant matters.
The TPD6S300A datasheet describes short-to-VBUS protection of signal paths, including the USB Type-C CC and SBU pins. In that mechanism, VBUS is the source of the abnormal exposure; the named signal paths are protected. Citing this function does not demonstrate regulation or overvoltage protection of the charger’s VBUS output itself. Keep the protected node explicit when transferring a claim into the evidence record.
These are three genuine engineering documents from one manufacturer, not three independent validations of a finished charger. None identifies the components inside an offered ChargeKeku product. Their purpose here is to explain why a shared protection label can hide different sensing, action and scope.

Build a claim-to-system-evidence matrix
Use one row for each distinct protection claim. Preserve the supplier’s exact wording and assign a claim ID before normalizing terminology. The fields below are a collection template, not completed test results. Attach the report revision and page or raw-record reference to every entry.
| Claim element | Record to retain | Boundary to preserve |
|---|---|---|
| Exact configuration | Model, sample, hardware, firmware and relevant BOM reference | A candidate component is not the finished-system configuration |
| Sensing and protection | Sensed quantity, detection node and protected node | Do not transfer signal-pin protection to VBUS |
| Operating envelope | Declared profile, protocol state, load and relevant conditions | Normal operation is distinct from the claimed abnormal event |
| Scenario authority | Approved laboratory scenario and stop-boundary references | Reference the controlled record, not execution instructions |
| Criterion basis | Qualified requirement for detection, action and recovery | No invented universal voltage or delay |
| Response record | Threshold crossing, delay, output action and maximum recorded protected-node exposure | Preserve separate quantities, units and uncertainty |
| Event correlation | Event ID, raw records, time alignment and measurement references | An unlinked shutdown is not proof of its cause |
| Recovery evidence | Event-clear reference, reset requirement, returned state and useful function | Component restart is not restored charging |
| Scope and owner | Supported, unresolved or outside-evidence flag; reviewer and disposition | One reviewed scenario does not cover all faults |
For each missing field, identify the question and the person who can close it. Do not fill an empty cell with a typical datasheet value or an assumed product setting. A configuration difference may explain why records disagree, but it still needs an explicit applicability decision.
The TPS25947 absolute-maximum ratings note states that those ratings do not imply functional operation beyond recommended operating conditions. Treat that warning as a component-document boundary, not as a way to derive a charger trip criterion. Neither an absolute-maximum rating nor a normal negotiated voltage should be substituted for the protection requirement under review.
For ordinary negotiated-output accuracy, use normal PPS setpoint acceptance. Its operating-point question is different from whether a specified protection event produced the required response at the claimed node.
Read the response and recovery as separate evidence
Keep a trip record and a recovery record linked by the same event ID. In the trip record, retain the reported sensed condition, protected-node action, criterion, alignment and uncertainty. Ask whether the evidence demonstrates the claimed response, rather than assuming that any loss of output proves correct overvoltage detection.
In the recovery record, retain how the report identifies the cleared event, any required reset or intervention, the returned operating state and restored useful function. Preserve repeated events and unresolved exceptions. These are requests for existing records, not directions for applying a fault, cycling an unsafe unit or reproducing a controller’s reset sequence.
| Evidence offered | What it can support | Appropriate next question |
|---|---|---|
| IC feature list or manufacturer waveform | A component mechanism example | Where is the exact finished-system configuration and event linkage? |
| CC/SBU protection record for an output-OVP claim | The named signal-path scope only | What evidence addresses the claimed output node? |
| Normal negotiated voltage or absolute maximum as the trip criterion | No established protection criterion | Which qualified requirement and sensing node apply? |
| Output action without trigger, timing or recovery context | The documented action only | Can the laboratory provide matched event and recovery records? |
| Configuration-bound records covering the named scenario and criteria | That scope after qualified review | Which conditions and claims remain outside the evidence? |
An incomplete recovery file is not a license to claim either safe restart or permanent failure. Keep the unknown visible. If the retained evidence instead shows an adverse result against an applicable criterion, route it to the designated engineering or safety reviewer; do not recast it as harmless missing paperwork.
Close only the claim that was reviewed
A useful disposition names the exact configuration, protected node, scenario reference and evidence accepted, along with unresolved conditions. Keep the original claim, laboratory response and reviewer’s dated decision together. Avoid a broad “OVP passed” label when the record supports only a specific event or component function. No worksheet here establishes certification or guarantees protection against every abnormal condition.
Where the issue is sustained power or temperature-related recovery, hand it to thermal derating and sustained-power evidence. Recovery after an input interruption is also a different question; neither topic should be relabeled as an OVP event merely because charging stopped.
For a ChargeKeku sourcing enquiry, request exact-model protection evidence with the claim wording, protected node and unresolved record fields. This asks for configuration-bound documentation, not an assurance that a particular protection architecture, certificate or test result exists.
Keep the enclosure closed. Do not short pins, interrupt feedback, change components, bypass safeguards or probe mains circuits to complete this matrix. A qualified laboratory must decide what work, if any, is necessary under its controlled procedures. The buyer’s evidence request does not authorize that work or choose its electrical limits.
Sources
- Texas Instruments — UCC28740 datasheet — selected reflected-output sensing and complete fault/reset context; March 2018 revision.
- Texas Instruments — TPS25947 datasheet — variant-specific lockout, clamp and recovery descriptions, plus absolute-maximum caveat; May 2026 revision.
- Texas Instruments — TPD6S300A datasheet — protected CC/SBU signal-path scope; June 2018 document, not current finished-charger validation.