Consider a hypothetical comparison: two suppliers quote different no-load power figures for chargers with similar output ratings. One report shows empty USB ports; the other includes an attached cable and protocol analyzer. Which charger consumes less power while unused? The smaller number cannot answer that question until the connection state and measurement method match.
A useful no-load report identifies what was connected, what the AC instrument measured, and how the result supports the purchasing requirement. This guide provides a report-review and sample-acceptance framework. It does not report measurements of a ChargeKeku product or establish a universal regulatory limit.
Define the state before comparing watts
The U.S. external-power-supply test procedure in Appendix Z defines no-load mode with the supply connected to mains and its output—or all outputs—not connected to a load. It separately defines standby and off-mode for the relevant switch conditions. Those definitions are useful evidence of why labels alone are insufficient; they should not be presented as worldwide terminology.
Ask the supplier to describe the physical and operating state, not merely select “standby” in a spreadsheet. Use a state record such as this:
| Report state | Record explicitly | Comparison boundary |
|---|---|---|
| Outputs disconnected | Every output port, manual-switch position and enabled auxiliary function | Candidate open-output comparison; confirm the applicable method |
| Cable attached, far end open | Cable identity and whether it contains powered electronics | Do not assume every cable is electrically invisible |
| Analyzer or test sink attached | How the instrument is powered, its settings and any maintained USB contract | A zero electronic-load setting does not establish the same state as an empty port |
| Device attached | Device identity, operating state and observed input demand | Treat as a connected-device scenario, not an interchangeable open-output result |
This classification is a procurement aid, not an additional regulatory test standard. Where a prescribed method applies, its connection instructions take precedence.
Keep the measurement boundary at the AC input
For a no-load consumption claim, request real input power in watts. Do not substitute a USB output-meter reading, the charger’s rated output wattage, or apparent input power in volt-amperes. Identify which quantity the instrument actually reports.
Draw the measurement boundary around the charger under test. If a fixture, analyzer or accessory receives power through the charger, record that arrangement. If equipment uses a separate supply, record that too. Do not “correct” a result by subtracting an assumed accessory consumption: either use the required connection state or obtain a separately justified measurement.
The basic wall-charger selection guide addresses output capability and product fit. Those are separate decisions. A lower unloaded input reading does not demonstrate better loaded efficiency, more sustained output power or better compatibility.
Ask for a low-power method, not extra decimal places
A display with many digits is not evidence that a small difference is meaningful. Appendix Z expressly references power-measurement uncertainty, low-power-mode measurement guidance and an average-reading method. A supplier report should therefore identify the method and instrument suitability rather than offer a cropped meter photograph.
Request the power-analyzer model, selected range, calibration status and uncertainty relevant to the reported operating condition. Ask how readings were averaged and how stability was assessed. If the result varies during the observation, the retained record should show that variation instead of presenting a convenient instantaneous minimum.
Agree the decision rule before comparing samples. If uncertainty leaves a result too close to the purchasing limit for a defensible decision, classify it as unresolved under that rule. Do not silently round it into acceptance or rank two suppliers on a difference the method cannot resolve.
Freeze a small, reproducible acceptance plan
The buyer and supplier should approve a written matrix before testing. Sample count, repetitions and acceptance limits depend on the purchase requirement; this article does not assign universal values.
- Identify the sample. Record the exact model, hardware revision, firmware or configuration where relevant, sample identifier and supplier lot. Different regional or port variants need their own applicability check.
- Declare every connection. List all USB ports, cables, fixtures, connected devices, switch positions and auxiliary functions. A photograph or simple setup drawing should agree with the written state.
- Specify the input and environment. Record AC voltage and frequency, relevant supply characteristics, ambient conditions and the laboratory method. Avoid comparisons that quietly use different input conditions.
- Define conditioning and timing. State the prior operating condition, warm-up or stabilization rule, observation window and averaging method. Do not compare a selected instant from one run with an average from another.
- Collect traceable evidence. Keep the input-power record, instrument settings, uncertainty statement and any deviations alongside the result. Include required repetitions rather than only the best sample.
- Apply the agreed disposition. Preserve the original result when a retest changes a cable, instrument range or connection state. Record what changed and why the new run is comparable.
Mains-side setup belongs to a qualified laboratory using suitable rated equipment and approved procedures. Keep the charger enclosure closed; procurement staff should not improvise energized mains connections to reproduce a supplier screenshot.

Turn incomplete evidence into the right decision
A missing setup field and a demonstrated product failure are different findings. Use a table that tells the supplier what evidence or corrective action is needed.
| Finding | Purchasing decision | What to request next |
|---|---|---|
| State, input, conditioning and method match | Compare under the agreed limit and uncertainty rule | Retain sample-level records and the disposition |
| One report includes an accessory or different port state | Do not rank the two results yet | Matched-state measurements or a clearly separate use-case claim |
| Averaging, range or uncertainty is absent | Hold the numeric claim | Complete method and raw-record evidence |
| A valid matched result fails the agreed requirement | Record a requirement failure | Supplier investigation and a controlled retest plan |
| Only a controller datasheet is supplied | Hold the finished-product claim | Evidence for the complete proposed charger |
Acceptance here means that evidence supports the declared purchasing scope. It does not prove safety, USB compliance, every market requirement or performance across an entire product family.
Do not transfer a component claim to a charger
Texas Instruments describes low no-load power capability for its UCC28740 flyback controller. That is a useful engineering reference, not a measurement of the complete charger being purchased. It establishes neither that the proposed charger uses this component nor what its total AC input consumption will be.
Require finished-product evidence tied to the offered model and configuration. Keep loaded thermal behavior in a separate evaluation, such as a charger thermal-derating test, rather than treating an unloaded result as proof of sustained-power capability.
Confirm regulatory scope separately
The U.S. Department of Energy’s external-power-supply overview defines the covered product category and identifies exclusions. Destination market, product classification and the applicable requirements must be established before selecting a legal limit or claiming compliance. This checklist is not a substitute for the complete applicable test procedure or conformity assessment.
For an OEM charger enquiry, send the supplier the intended markets, exact port configuration and required report states. Request the agreed limit and method, sample identities, setup record, raw measurements, uncertainty and disposition. A comparable evidence package is more useful than the lowest unexplained wattage in a quotation.
Sources
- U.S. eCFR — Appendix Z: Uniform Test Method for Measuring the Energy Consumption of External Power Supplies; operating-state definitions and measurement-method context.
- U.S. Department of Energy — External Power Supplies; product scope and exclusions.
- Texas Instruments — UCC28740 product documentation; a component-level no-load capability example, not finished-charger evidence.